Copolymer Emulsion For Fire Proof Coatings

Copolymer Emulsion for Fire Proof Coatings

    Specifications
    HS Code 340394
    Flammability Resistant to fire
    Adhesion Good adhesion to substrates
    Coating Film Hardness Moderate to high hardness
    Weather Resistance Fair to good weather resistance
    Chemical Resistance Some resistance to chemicals
    Viscosity Controllable viscosity
    Drying Time Relatively short drying time
    Film Forming Property Forms a continuous and smooth film
    Water Resistance Good water - resistance
    Opacity Sufficient opacity for coating

    As an accredited Copolymer Emulsion for Fire Proof Coatings factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 20 - kg bucket packaging for Fire Proof Coatings Copolymer Emulsion.
    Storage **Storage Instructions for Fire - Proof Coating Copolymer Emulsion** Store the copolymer emulsion for fire - proof coatings in a cool, dry place. Keep it away from direct sunlight and heat sources to prevent premature polymerization. The storage temperature should be maintained between 5 - 35°C. Ensure the containers are tightly sealed to avoid contamination and evaporation, preserving its quality and fire - proofing efficacy.
    Shipping Copolymer Emulsion for Fire Proof Coatings is shipped in sealed, corrosion - resistant containers. It's carefully handled to prevent spills. Shipments follow strict chemical transport regulations to ensure safety during transit.
    Free Quote

    Competitive Copolymer Emulsion for Fire Proof Coatings prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615380400285 or mail to sales2@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615380400285

    Email: sales2@liwei-chem.com

    Copolymer Emulsion for Fire Proof Coatings Copolymer Emulsion for Fire Proof Coatings
    General Information
    Historical Development
    Since ancient times, human beings have tried many things to prevent fires. In modern times, their skills have gradually refined, and many fireproof materials have been invented. At first, sediment was painted on the wall, followed by gypsum and asbestos, but the drawbacks are endless. And the chemical industry is booming, and the use of resin has become the world's most important. In the 20th century, scientists dedicated themselves to developing, and copolymer emulsions have gradually gained popularity. This emulsion is made up of a variety of monomers, which not only has excellent adhesion, but also resists high temperature and is convenient for construction. With the innovation of synthesis technology, the performance has been improved day by day. Today, copolymer emulsion fire protection coatings have been widely used in high-rise factories and underground facilities, with great safety effects. From simple things at the beginning to cutting-edge materials today, it can be seen that its innovation and inheritance have been through generations of intensive research and has eventually become a great career.
    Product Overview
    This product is a special copolymer emulsion for fire retardant coatings. It is refined and polymerized with a variety of high-performance monomers. It is milky white and translucent and has a delicate texture. Its process takes part in modern polymer technology, adding fire to the toughness of the coating, and the coating film is dense, which can effectively inhibit the spread of flame and block heat conduction. When applied, it is easy to harmonize with various types of fillers and additives, with good harmony and simple construction. Its water resistance, alkali resistance and weather resistance are both excellent. It is still structurally stable in high temperature and harsh environments, and is not easy to crack and peel. It integrates safety and environmental protection, is non-toxic and harmless, and meets the current fire protection specifications in many fields such as construction, transportation, petrochemical, etc. In addition, it can ensure the tranquility of facilities and protect life and property. It is
    Physical & Chemical Properties
    This copolymer emulsion is formed by the copolymerization of various monomers. Its body is uniform, in a milky white liquid state, slightly viscous and flowing freely. It is stable at room temperature, has no foreign gas escape and dissipation, and is not easy to precipitate and stratify when left for a long time. Its density is slightly higher than that of purified water, and it is easy to apply. It does not burn in case of fire, but gradually loosens in case of high temperature, precipitates foam, has the effect of expansion and heat insulation, can flame retardant and suppress smoke, and remove fire spread. Robust chemical properties, resistant to acid and alkali erosion, resistant to ultraviolet radiation, and does not react violently with common building materials or coatings. Easy to reconcile with dry powder and additives, good compounding performance. Good water solubility, diluted with water, and easy to clean and recycle. The overall physical and chemical properties are suitable for fireproof coatings,
    Technical Specifications & Labeling
    This "Fire Proof Coatings" copolymer emulsion is specially made for fire retardant coatings. Its color is milky white, its appearance is uniform, and there are no different sundries. The solid content ratio (solid content) is about 50 ± 2%, the pH value is between 7 and 9, and the viscosity is suitable. It is easy to coat and spread. The particle size is small and evenly distributed, often at 100 to 300 nanometers, to ensure that the coating film is delicate and dense. The ionic type is mostly anionic, with good compatibility, excellent water resistance, alkali resistance and weather resistance. The finished product is non-toxic and tasteless, environmentally friendly in line with European standards. Its salting out stability and chemical compatibility are good, and it can be integrated with a variety of pigments and fillers and additives. The packaging is mostly sealed in 25kg and 50kg plastic drums, stored in a cool place, with a quality assurance period of one year. The processing temperature can be operated from 5 ° C to 35 ° C, which is convenient for engineering applications.
    Preparation Method
    Styrene, acrylate and vinyl monomer are selected as raw materials, accompanied by emulsifier and deionized water, and combined in a reactor. Stir slowly, the temperature rises to 60 to 80 degrees Celsius, and an initiator such as ammonium persulfate is added dropwise to form an emulsion. Then control the dropwise addition rate and adjust the pH value to make the copolymerization reaction proceed uniformly. To improve the fire resistance, an inorganic flame retardant such as aluminum hydroxide can be added to inject the flame-suppressing effect. In various reactions, the catalytic mechanism is based on free radical initiation, and the monomer's free radical polymerizes to form a copolymer polymer. The dispersed microspheres are suspended in water and cross-linked to each other to form an emulsion. Finally, it is cooled to room temperature and filtered off the residue to obtain the finished product of the copolymer emulsion for the fireproof coating, which is firm and dense in quality and fire-resistant.
    Chemical Reactions & Modifications
    Copolymer emulsion, used in fire retardant coatings, its chemical reaction and modification, the function is very good. At first, acrylate and styrene monomers are prepared for copolymerization, and polymerized by emulsion to form a polymer with fine particle size and uniform distribution. In the meantime, the emulsifier guides, the monomers break bonds and connect, the chain changes, and the properties are different. To strengthen its fire resistance, nitrogen and phosphorus elements, or halogen-containing components, are introduced to give it a flame retardant mechanism. The way of modification, or the grafting method, adds new bases to the main chain, or the cross-linking method, promotes the close branching structure, so that the decomposition temperature rises and the carbonization layer is dense. Compounds containing silicon and oxygen structures can also be introduced to give the coating film high temperature resistance and resistance to melting. This kind of emulsion is flexible and flexible, does not melt in case of fire, can block heat insulation and flame, and is actually in the field of fire protection, making it safe and of great benefit.
    Synonyms & Product Names
    Synonyms and trade names are common in the circulation of goods. In terms of Copolymer Emulsion for Fire Proof Coatings, its synonyms can have multiple ends. For example, copolymer emulsions, refractory paint emulsions, polymer emulsions for flame retardant coatings, etc., are all interoperable. Cover copolymer emulsions refer to the copolymerization of various monomers; refractory paint emulsions, which illustrate the fire protection of their uses; polymer emulsions for flame retardant coatings, which apply their mechanism to resist fire. Trade names are numerous, or depending on the brand, they are called FireGuard Copolymer, ResistFlame Emulso, ProtecShield 225, etc., or SafeCoat Polymer, ThermoStop Emulsion, etc. depending on the use. Although the names are different and the quality is the same, they are used for refractory coatings to prevent flame attack and improve safety. Businesspeople must carefully distinguish their synonyms and proper names, so as to clarify what they refer to, avoid misuse, and gain access to the market, which is conducive to transactions.
    Safety & Operational Standards
    It is Copolymer Emulsion that is an important material for fire retardant coatings and is used in fire protection projects, which is really beneficial. However, between operations, safety must be careful and norms should not be ignored. Keep this material in a cool and dry place, away from fire sources and high temperatures, and seal the container to prevent it from leaking. The operator should wear protective clothing, mask the mouth and nose, gloves in hand, and goggles to prevent it from sticking to the skin and entering the eyes. In case of escape in the air, ventilators should be turned on, or operated in the open air, so as not to cause harmful gases to gather and disturb people. If it touches the skin by mistake, wash it with water and soap; if it splashes into the eyes, rinse it with water and seek medical attention immediately. Be careful not to dump the remaining waste into the city drainage. It is advisable to collect and dispose of it according to regulations. Operating utensils used up, clean in time, do not leave residual stains. Handling and storage, the action needs to be slow, to avoid violent collision and overturning. In case of leakage, quickly with absorbent materials containment, collection and disposal, do not let it flow into the water and soil. Fire prevention is essential, do not approach the open flame, the operation area is smoke-free, tools should be fire-proof. In case of abnormal odor or discomfort, it is advisable to stop the operation and seek guidance. With the above, if you follow the norms, you can ensure the safety of the operation, prevent problems before they happen, and then it will be beneficial to people without regret.
    Application Area
    The copolymer emulsion is what today's fire retardant coatings rely on. It is stable in nature, strong in bonding, and has a wide range of applications beyond the ordinary. It can be seen in high-rise buildings, factory warehouses, subway tunnels, and petrochemical equipment. This emulsion is integrated with various substrates, adding them together to form a coating film, which is non-flammable in case of fire, heat-resistant and insulated, and can prevent the spread of flames and reduce disasters. And because it is both environmentally friendly and non-toxic, and easy to construct, it is highly relied on by modern construction and industrial fields. It is suitable for indoor and outdoor walls, steel structure beams and columns, or wood and plastic surfaces. It is a good material for safety protection with copolymer emulsion as a fire retardant coating. It is widely used in public facilities and important projects, and its value is increasing.
    Research & Development
    In ancient times, we have lived in peace and made progress, and we must first prevent problems before they happen. Today, due to the frequent fires in the world, there are many industrial research and refinement techniques to make fire-proof coatings, especially copolymerized emulsions. Its properties are flexible and solid, not only has good bonding, but also has the power of high temperature flame retardant resistance. Scholars have explored the polymerization mechanism, prepared the proportion of monomers, integrated multi-component functions, and focused on the optimization of the microstructure of the emulsion. After repeated tests, fine-tuning the emulsified formula has made it evenly distributed, moderate particle size, and greatly increased bonding strength, which can also be used in synergy with inorganic flame retardant materials. Because it is applied to building materials, it can reduce the raging fire and protect people in Antai. Although this road is difficult, scientific researchers work day and night to solve key problems, not only widely leveraging the wisdom of the past, but also having the courage to innovate, making the copolymer emulsion fireproof coating increasingly perfect, which is a help for social security.
    Toxicity Research
    A new type of copolymer emulsion is widely used in refractory coatings for both bonding and high temperature resistance. However, the substance is new, and its harm to the human body and the environment must be examined. By taking its samples, according to modern toxicological methods, its acute, skin, inhalation and sensitization reactions were investigated. The experiment was carried out in mice, and the dose was increased. It was observed that there was no death or abnormal behavior. In the skin test, no redness, swelling and irritation were seen. The solution was tested with in vitro cells, and the cell survival rate was high, and there was no significant poisoning. Inhalation test, the atomized gas did not cause animal discomfort. However, the continuous contact experiment needs to be further studied, and it cannot be cut off immediately. Its overall toxicity is low, making it safe to use in refractory coatings. It is recommended to operate according to procedures to ensure the well-being of users and the environment.
    Future Prospects
    Easy to move, technology is new, fire protection benefits and safety is of great importance. Today, there are copolymer emulsions with excellent performance, which can not only increase the adhesion of the film, but also give it a good flame retardant effect. Looking forward to the future, the environment is guaranteed, and the low-cost and toxic emulsion materials will be subject to green. Sophisticated, multi-functional, or can be combined with new materials, which is intelligent, repair and self-healing effect. Overseas market development, low-quality, and newcomers can be in the forefront due to their needs. Large-scale, copolymer emulsions are used for fire protection, which is expected to lead to the improvement of the economy, promote the well-being of human settlements, and benefit the community.
    Where to Buy Copolymer Emulsion for Fire Proof Coatings in China?
    As a trusted Copolymer Emulsion for Fire Proof Coatings manufacturer, we deliver: Factory-Direct Value: Competitive pricing with no middleman markups, tailored for bulk orders and project-scale requirements. Technical Excellence: Precision-engineered solutions backed by R&D expertise, from formulation to end-to-end delivery. Whether you need industrial-grade quantities or specialized customizations, our team ensures reliability at every stage—from initial specification to post-delivery support.
    Frequently Asked Questions

    As a leading Copolymer Emulsion for Fire Proof Coatings supplier, we deliver high-quality products across diverse grades to meet evolving needs, empowering global customers with safe, efficient, and compliant chemical solutions.

    What are the main ingredients of Copolymer Emulsion for Fire Proof Coatings?
    Copolymer Emulsion for Fire Proof Coatings, translated as copolymer emulsion for fire retardant coatings, is essentially a modern chemical material, specially used for building and facility protection. Looking at its composition, it must be based on organic polymers, taking acrylates, styrene, ethylene, vinyl acetate and various monomers, copolymerizing with each other to form a polymer chain. The proportion of the monomers is flexible and depends on the desired properties. In the process of polymer double emulsion, an emulsifier is supplemented to make the hydrophobic monomers uniformly dispersed in water and cross-linked with each other to form a stable colloid. The emulsion has fine particle size and strong cohesion, which is the basis for film formation.
    Furthermore, the characteristics of fire retardant coatings go beyond film formation. Fire resistance, heat resistance and weather resistance all depend on the support of this emulsion. Such as aluminum hydroxide, magnesium hydroxide and phosphorus-based flame retardants are often blended with emulsions to give flame retardant power; titanium dioxide and binder are also used as auxiliary materials to increase their covering and adhesion. Therefore, when the coating film is heated, the emulsion is heated and expanded, foamed, and a porous carbonized layer is formed. This layer can block heat flow, delay the heating of the substrate, and effectively defend against flame invasion. Such a structure is due to the superior performance of the copolymer emulsion.
    Its production is mostly based on advanced emulsion polymerization technology, temperature control, stirring, and additive ratio, all of which need to be precisely prepared. The appearance is milky white or translucent, and the viscosity is moderate, which is easy to construct. It is both environmentally friendly, non-toxic and low-taste, and conforms to the green concept of modern building materials. The common ones in the market are mostly acrylic acid-vinyl acetate and styrene-acrylic acid copolymer emulsions. Such emulsions have good stability, resistance to aging and pollution, and can be firmly combined and well protected when applied to steel structures, wood, concrete and other substrates.
    To sum up, copolymer emulsions are the core of fire retardant coatings, and many components cooperate to give them ideal fire resistance. The craftsmanship is becoming more and more exquisite, and the ingredients are each developing their strengths. The wonders of this emulsion are becoming more and more obvious to the world.
    How does Copolymer Emulsion for Fire Proof Coatings improve the performance of fire retardant coatings?
    In the past, man-made fire retardant coatings were mostly made of inorganic or organic resins. Although they could resist fire, they were easy to crack and peel off, and the adhesion was not strong, and the effect would be reduced after a long time. Today, copolymer emulsions are used in them, and the performance of coatings has been greatly improved. Copolymers are made from two or more monomers, which have their own advantages. They are flexible and solid at the same time, and bad is good. Its performance is as good as left for fire retardant coatings.
    Copolymer emulsions are soft and tough. They are coated on materials and expand and shrink with the surface of the material without cracking. The fire is intense, and the paint expands into bubbles to form a dense carbonized layer, which is firmly attached to the base surface by the adhesive force of the emulsion. In the past, monomer emulsions were weak when they were soft, brittle when they were just too soft, or brittle when they were In this copolymer emulsion, high temperature resistant monomer and hydrophilic monomer are used together, and the molecular chain is interwoven, which not only resists high temperature weight loss, but also waterproof and wet peeling. Therefore, the fireproof coating made of the copolymer emulsion does not flow or peel off when the flame is burned, and the carbon layer is thick and dense, effectively blocking heat transfer.
    In addition, the modified copolymer emulsion can introduce phosphorus, nitrogen, silicon and other elemental monomers. When heated and exposed to fire, flame retardant gases are released, which helps to form a carbide layer and improve protection efficiency. It has strong compatibility with fillers and expansion agents, which can make the formula changeable, and is suitable for various substrates such as steel and wood. The weather resistance is also greatly increased, and the wind, rain and sun do not change color and peel, and the service life is extended.
    The copolymer emulsion is easy to disperse in water, green and environmentally friendly, and convenient for construction. In the field of modern building fire protection, its function is particularly useful. This emulsion makes up for the traditional resin, and integrates softness, solidification, adhesion and flame retardancy. To make a good fire retardant coating, the copolymer emulsion should be used as the base, supplemented by various additives, to effectively improve the adhesion, heat resistance, flame retardancy, durability and other elements. It is widely used, which is conducive to the safety of human settlements and helps the society to thrive.
    What types of fire retardant coatings are suitable for Copolymer Emulsion for Fire Proof Coatings?
    Copolymer Emulsion is an emulsion made from the copolymerization of two or more monomers. Its fine texture and excellent performance are widely adopted by contemporary coating technology. When it comes to fire protection, this emulsion can be used in a variety of fire retardant coatings, especially in the categories of intumescent, non-intumescent, fire-resistant sealing, flexible coating, steel structure fire protection, wood structure fire protection, etc. The cover is widely used because of its strong bonding force and good film-forming properties. It can be evenly distributed on the surface of the substrate and enhance the adhesion and durability of the coating.
    Inflated fire retardant coatings depend most on the dispersion and film-forming properties of the emulsion. When coated, it can quickly expand in case of fire to form a porous heat insulation layer, delaying temperature rise, and protecting the substrate under flames, especially for steel, wood and other structures. Non-expansion fire retardant coatings are still strong and fire-resistant. The emulsion contains polymer chains, giving the coating a dense structure, blocking the intrusion of heat flow and flame, and is suitable for the protection of cement, concrete and other substrates. Sealing fire retardant coatings are wrapped around doors and windows, gaps, and grooves. They need to be firmly bonded and expand and contract with slight changes in the structure. Copolymer Emulsion has a flexible molecular structure, which can help it resist deformation and aging, and slow down the spread of fire.
    There is also a flexible coated fireproof material, which is used to coat pipelines, cables, and air ducts. It needs to be thinly coated and supple, and the film is formed without cracking. The copolymer emulsion makes the interlayers bond tightly, which meets the needs of both flexibility and fireproof. As for the special fireproof coating for steel structures, this emulsion helps to improve the combination with steel, enhance the performance of high temperature resistance and weathering resistance, and greatly increase its protective life. For fireproof wood structures, the emulsion can quietly penetrate into the fibers. After film formation, it is both flame retardant and color-preserving, without compromising its beauty.
    To top it off, Copolymer Emulsion is suitable for a variety of fireproof coatings due to its excellent physical and chemical properties. It can be flexibly prepared according to needs to increase the stability, fire resistance and aging resistance of the coating. This emulsion is an essential material for fire prevention in modern buildings, and helps to improve fire prevention.
    What issues should be paid attention to during the use of Copolymer Emulsion for Fire Proof Coatings?
    Copolymer Emulsion is suitable for the use of fire protection coatings, with excellent performance and should be used with caution. When it is applied, it is necessary to pay attention to several ends, which is very critical. The choice of cover material, the first storage suitable place. The storage capacity should be sealed, away from fire sources, heat sources and direct sunlight, and a cool place at room temperature is preferred. If the emulsion may be unstable and the shape changes in case of high temperature and heat, the fire resistance will be impaired.
    Second, the construction environment should be clean and dry, and the humidity should not be too high. The wall or substrate should be flat and solid, free of oil, dust, water stains and loose animals, before it can be applied. If the base surface contains water, the emulsion will be difficult to bond and may lose its characteristics. It is necessary to measure its moisture content to comply with the specifications. In addition, special brushes, rollers, and sprayers should be used for coating. The utensils need to be clean. Impurities can easily destroy the uniformity of the emulsion and cause fire failure.
    In the process, it should be applied thinly in batches, and it must be dried in the front and then applied in the back. Thick coating is difficult to dry, the surface is dry and the inside is wet, and it causes cracking and peeling. Room temperature and ventilation conditions affect the curing of the emulsion. If the temperature is too low, the construction should be suspended. For each application, the interval between layers is subject to actual drying, and it is not allowed to be operated. The ingredients should be in accordance with the manufacturer's instructions. It is not advisable to mix other ingredients without authorization, such as toner or quick-drying agent. Mixed with other substances, the variability and fire resistance will be reduced.
    After using the finished utensils, it is advisable to wash them with water immediately, especially do not wait for the emulsion to dry and solidify. If it coagulates, it will be difficult to remove. Construction personnel must wear gloves and masks to prevent the emulsion from touching the skin and entering the eyes. In case of accidental contact, rinse with clean water and dispose of it with caution.
    Wait until the coating is completely dry and solidified before it can be put into use. The emulsion coating is not dry and has not yet had the effect of resisting fire. Do not rashly ignite the test. If it is dry and qualified, the effect will be proved.
    Follow all the essentials to ensure that the function of Copolymer Emulsion in the fireproof coating is fully exerted and the effect of long-term safety is achieved.
    What are the storage and transportation requirements for Copolymer Emulsion for Fire Proof Coatings?
    Copolymer Emulsion is used for fire retardant coatings, and its storage and transportation are strictly regulated and cannot be ignored. It is a kind of emulsion, suitable for storage at constant temperature, not resistant to high temperature freezing and cracking, and also afraid of hot sun exposure. In case of high temperature, the emulsion will be separated, and the properties will deteriorate. In case of severe cold, frostbite will dehydrate water, viscosity will be reduced, and it will be difficult to recover. When transporting and storing, it must be placed in a cool and ventilated place. Room temperature is good, and the temperature should be maintained between five and thirty-five degrees. After this, the product is easy to fail, so it can't be used.
    Utensils are mostly made of plastic or enamel, not metal. The cover must be tight, dustproof and moisture-resistant. If impurities are mixed in, the emulsion is easy to change. Buckets and cans are stacked neatly and orderly. They must be five inches away from the wall and six inches away from the ground. Avoid mixed storage with acid and alkali. Coffee, food, and flammable things should not be accessible. Do not turn upside down, and cannot be pressed heavily to prevent damage to the container. If the emulsion leaks, it should be buried with sand or sawdust to remove it thoroughly to prevent slipping and environmental pollution. All kinds of handling, be sure to handle it slowly and lightly. Do not throw it violently to prevent shock and foaming. If the journey is long, the rain cloth is protected, and the rain penetrates, the quality will change immediately. Why is it useful?
    During transportation, vehicles are prohibited from being loaded with sources of fire and flammable products. In case of accidents or high-temperature road surfaces, transportation should be suspended. Fire-fighting equipment must be installed in the storage warehouse to prevent untimely accidents. And the shelf life is limited to six months. The overdue latex is gradually losing its effectiveness. It must be rotated in batches, first in, first out. Each time it is unsealed, it must be used up as soon as possible. The remaining seal should not be exposed for a long time. If it is invaded by air dust and moisture, it will deteriorate and be afraid of life. The acceptance mark is clear, the batch can be checked, and it does not meet the standards. It is not suitable to put it into production.
    In short, this emulsion is stored and transported. It is better not to be lazy. Always follow the system and prevent problems before they occur. It is to ensure the quality of fireproof coatings and cultivate the foundation of Bangjia's safety.