Product Name: Halogen Free Flame Retardant Cable
Other Names: HFFR Cable, LSZH Cable
Recommended Use: Electrical wiring for indoor and outdoor installations, areas with fire safety demands
Supplier: Fill with manufacturer details, address, and contact number
Emergency Contact: Fill with local emergency telephone numbers
Product Code: Internal tracking number and batch information
Classification: Generally classified as non-toxic, non-hazardous under GHS for typical use, no significant acute hazards
Primary Hazards: May emit irritating or toxic gases in extreme fire conditions, especially oxides of carbon and nitrogen
Route of Entry: Dust, fumes generated from cutting, burning, or excessive heating
Most Important Symptoms: Eye or respiratory tract irritation from fine dust, rare skin reactions
Polymeric Matrix: Polyolefin compounds (PE/EVA or PP based)
Flame Retardant Additives: Magnesium hydroxide or aluminum hydroxide, mineral-based fire suppressants
Filler Materials: Calcium carbonate, silica
Stabilizers: Minor levels of phosphites or phenolic antioxidants
Colorants: Organic and inorganic pigments for identification
Other Components: Trace moisture, no halogen compounds present
CAS Numbers: Major raw materials: Polyethylene (9002-88-4), Magnesium hydroxide (1309-42-8)
Eye Contact: Rinse carefully with clean water for several minutes, seek medical help if irritation persists
Skin Contact: Wash contacted areas with soap and water, seldom causes allergic response
Inhalation: Move affected person to fresh air, seek medical help if breathing difficulty continues
Ingestion: Unlikely route, rinse mouth out and seek medical advice if symptoms occur
Suitable Extinguishing Media: Water spray, foam, dry powder, carbon dioxide
Unsuitable Media: None known for cable itself
Hazardous Combustion Products: Release of carbon monoxide, carbon dioxide, water vapor, small quantities of organic decomposition byproducts
Protection for Firefighters: Wear self-contained breathing apparatus and full protective gear
Fire Fighting Instructions: Apply cooling water to exposed surfaces to reduce smoke and slow fire spread, keep run-off water collected
Flash Point: Above typical ambient temperatures, cable does not ignite easily
Explosion Risk: None under normal use or transport
Personal Protection: Gloves, goggles, and dust mask if fragmented material is present
Methods for Containment: Collect solid fragments and dust by sweeping or vacuuming
Cleanup Procedures: Place waste material in suitable container for recycling or disposal, ventilate area if there is significant dust
Environmental Precautions: Avoid discharge to waterways, most components have low environmental mobility
Precautions for Safe Handling: Minimize dust generation and accumulation, always handle with gloves to avoid skin irritation
Storage Conditions: Store in a cool, dry place away from direct sunlight and strong oxidizers, stacking to be stable and secure
Specific Uses: Apply as supplied for electrical installations, avoid overheating or open flames during installation
Packing Materials: Store in original reels, drums, or pallets to prevent physical damage
Exposure Limits: No specific exposure limits for base compound components under normal workplace conditions
Ventilation: Sufficient local ventilation during cutting or stripping operations
Personal Protective Equipment: Gloves for handling, eye protection for mechanical operations, dust mask for cutting
Hygiene Measures: Wash hands after handling, avoid eating in working areas
Monitoring: Routine workplace air quality checks in dusty environments
Appearance: Typically solid, flexible, and colored according to service use
Odor: Mild waxy or neutral
Melting Point: 80°C to 130°C depending on polymer
Density: 1.3 – 1.6 g/cm³
Solubility: Insoluble in water, not intended for use in solvents
pH: Not relevant for solid product
Boiling Point: Not applicable
Flash Point: > 300°C
Self-Ignition Temperature: > 350°C
Vapor Pressure: Not applicable
Particle Size: Not finely divided, unless mechanically processed
Chemical Stability: Stable at ambient temperatures and pressure in storage or use
Conditions to Avoid: Prolonged heat above melting point, exposure to open flame or strong oxidizers
Materials to Avoid: Strong acids, strong oxidizing agents
Hazardous Decomposition: Produces carbon oxides, water, traces of hydrocarbons under combustion
Polymerization: Not relevant for finished cable products
Acute Toxicity: Very low for finished cable
Chronic Effects: No evidence of chronic health risks from cable exposure
Irritation: Mechanical dust may cause mild eye or respiratory irritation
Sensitization: No reports of skin sensitization in standard industrial exposure
Mutagenicity / Carcinogenicity: Key ingredients not classified as mutagenic or carcinogenic under REACH or OSHA
Inhalation: Fumes from over-heating may cause temporary irritation
Toxicity to Water Life: Low aquatic toxicity for primary components
Persistence: Not readily biodegradable, largely inert
Bioaccumulation: No significant risk due to low solubility
Mobility: Moves little in soil, tends to remain where deposited
Decomposition Products: Inert material in landfill situations, will slowly break down through physical or thermal action
Waste Handling: Collect and reuse or recycle cable whenever possible
Landfill Disposal: Acceptable, as material is not classified as hazardous waste
Incineration: Energy recovery incinerators suitable, but must control smoke and emissions
Safe Disposal Codes: Refer to local or national legislation for plastics
Packaging Disposal: Recycle cardboard, reels, or drums whenever possible
UN Number: Not regulated for land, sea, or air transport
Transport Hazard Class: Not classed as dangerous goods
Packaging Requirements: Standard palletization or reel transport, secure loads to avoid shifting
Special Precautions: None required in normal transit
Environmental Hazards: None of significant concern in finished cable form
REACH Status: Finished cable does not contain listed substances of very high concern
OSHA Hazard Class: Not classified as hazardous
RoHS Compliant: Yes, no restricted substances present
Labelling Requirements: No hazard symbol or special labeling according to international transport or supply regulations
Other Requirements: Users should check for any updated local compliance needs before disposal or large-scale installation